Item specifics
- Housing material Plastic
- Weight 273 g
- Sensor type High frequency (HF); mixed-light measurement
- Installation Ceiling; surface-mounted AP; indoors
- Reach Radial and tangential: up to Ø12 m (113 m²)
- Detection angle 360°; aperture angle 160°
- Optimal mounting height 2.8 m
- Maximum mounting height 4 m; current range 2.5–4 m
- Time setting 10 s–60 min; IQ 5–20 min; pulse 2 s / pause 8 s
- Twilight setting 2–2000 lx; Teach and daytime mode
- Sensor system Reach electronically adjustable in the app
- Sneak-by guard Yes
- Segment masking No individual segment masking
- Manual control S button input; semi- or fully automatic mode; button cable <50 m
- Relay load 2000 W incandescent/halogen; low-voltage halogen 1000 VA; LED/ECG 600 W
- LED load (W) 600 W LED/ECG; max. 50 units; total capacitance <220 μF
- Parallel connection Bluetooth Mesh; manual permits up to 10 sensors via L′
- Output type COM1; one non-floating switched-live relay; ON/OFF
- Interface & control COM1 relay; Bluetooth Mesh groups and neighbouring groups
- Settings Bluetooth Mesh; STEINEL Connect app; test mode
- Voltage 220–240 V AC, 50–60 Hz
- Operating temperature −25…+50 °C
- IP rating IP54
- Dimensions (W×H×D) 123 × 123 × 57 mm (length × width × height)
- Warranty 5 years
- Colour / RAL White; RAL 9003
- Manufacturer SKU 086763
- EAN 4007841086763
Product Description
HF detection for rooms with partitions
The STEINEL HF 360-2 COM1 AP is a white Control PRO II presence detector for automatically switching indoor lighting. Its 5.8 GHz high-frequency technology and 360° detection can register movement through glass, wood and lightweight partitions. This makes it useful in washrooms with cubicles, changing areas and ancillary rooms where a screen may obstruct a direct view of the person moving. Stairwells and kitchenettes are further applications in which lighting can follow how the room is being used.
Adjust the coverage to the room
The manufacturer specifies a maximum detection diameter of 12 m for both radial and tangential movement, corresponding to a circular area of up to 113 m². Actual coverage depends on mounting height, the layout of the room and the selected sensitivity. Reach is adjusted electronically in the app. During commissioning, check movement on the other side of lightweight partitions as well as inside the intended room, since HF signals can pass through these materials. Test mode helps assess the chosen position before normal operation is configured.
Use the available daylight
The white version combines HF detection with mixed-light measurement, allowing the switching decision to take the room's existing illumination into account. Its 2–2000 lux response threshold can be selected to suit the application, while Teach stores the measured light level at the time it is activated. This is useful when setting up a room with windows or changing natural light. Daytime operation is available when movement should trigger the lighting regardless of brightness. In fully automatic mode, the detector controls both switching on and switching off according to the selected conditions.
Bluetooth Mesh groups and manual control
Bluetooth Mesh provides wireless configuration and interconnection with compatible devices using the STEINEL Connect app. Group settings coordinate operation, while each detector's reach can be adjusted individually. The neighbouring-group function helps coordinate lighting between adjoining areas. Semi-automatic operation leaves switching on to the user and allows the sensor to switch the lights off after the selected delay. An external button can be connected to input S for manual operation; the operating instructions specify a cable length of less than 50 m between the sensor and button.
Select the timing and connected load
The stay-on time after the last detected movement can be set from 10 seconds to 60 minutes. IQ mode learns from use and adjusts the delay within a 5–20 minute range. Pulse mode provides a two-second output followed by an eight-second pause, for example when controlling a staircase timer. COM1 supplies one switched-live relay output. For LED lamps and electronic control gear, the manual specifies 600 W, no more than 50 units and total capacitance below 220 μF; all three limits must be respected together. The incandescent and halogen lamp rating is 2000 W.
Surface mounting on the ceiling
The AP housing is designed for surface mounting on indoor ceilings, including rooms where a recessed detector is unsuitable. The current product specification gives a mounting range of 2.5–4 m and an optimum height of 2.8 m. Its IP54 enclosure is specified for this indoor application. A magnetic sensor module allows access to the load module during fitting. When choosing the position, follow the manual's minimum separation of three metres from Wi-Fi routers or access points. Connection to the 220–240 V supply must follow the manufacturer's COM1 wiring diagram and the applicable installation requirements.
Gallery image context
The main photograph shows the offered white HF 360-2 COM1 AP sensor, article 086763. The additional white-housing detail photograph illustrates the construction of the HF 360-2 family; it does not indicate a different colour or package for the offered product. The washroom photograph is a manufacturer application example in which the exact sensor model, colour and COM interface have not been confirmed. Room furnishings are not included with the sensor. The article number and this product specification identify the offered variant.