Steinel
STEINEL True Presence COM1 AP surface ceiling presence sensor 360°, Bluetooth Mesh, IP54, black (085513)
- Indoor lighting
- Outdoor lighting
- Technical lighting
- LED bulbs
- LED strips and profiles
- LED power supplies
- Motion sensors and dusk switches
- Motion sensors
- Other
- Sale
Your shopping cart is empty!
Item specifics
- Weight 270 g
- Detection angle 360°; aperture angle 160°
- Time setting 30 s–60 min per manual; current table lists 20 s minimum; pulse 2 s/8 s
- Sneak-by guard Yes
- Segment masking No individual segment masking or mechanical adjustment
- Manual control S pushbutton input, cable <50 m; compatible Bluetooth Mesh buttons; ON/OFF and timed commands
- Relay load Resistive 2000 W; electronic ballasts 600 W per manual; low-voltage halogen 2000 VA
- LED load (W) Up to 600 W per COM1 manual; max. 8 LED/fluorescent lamps per exact article table; 220 µF
- Output type One COM1 switched-live relay output; non-floating; no dimming
- Interface & control COM1 relay; Bluetooth Mesh groups and neighbouring-group function
- Settings STEINEL Connect app via Bluetooth
- Colour / RAL Black; RAL 9005
- In the box True Presence AP sensor, safety information and quick-start guide
- Manufacturer SKU 085513
- EAN 4007841085513
- Sensor type High-frequency True Presence sensor; micro-movement detection
- Presence detection zone True Presence micro-movements Ø9 m (64 m²), mounting height up to 4 m; ordinary presence Ø15 m (177 m²)
- Motion detection Radial and tangential up to Ø15 m (177 m²)
- Sensor system Electronic range adjustment in app; 9 scenarios, 1 and 2 without True Presence
- Application Indoors
- Installation Ceiling, surface-mounted AP
- Installation height 2–12 m per current table; recommended 2.8 m; True Presence up to 4 m
- Light-level setting No onboard light measurement or Teach; brightness-dependent control requires compatible external measurement
- Voltage 220–240 V AC, 50–60 Hz
- Parallel connections Bluetooth Mesh; master/master or master/slave; manual specifies up to 100 network devices
- Functions Automatic/semi-automatic, grouping, test, presentation mode, pulse
- Housing UV-resistant plastic
- IP rating IP54; AP surface-mounted version
- Dimensions 123 × 123 × 45 mm (width × face height × projection)
- Temperature range −20…+50 °C
- Warranty 5 years
- Wattage 1 W per current table; manual <1 W
- RF frequency True Presence 7.2 GHz; Bluetooth 2.4–2.48 GHz
Product Description
Presence detection during quiet activity
STEINEL True Presence COM1 AP is a black surface-mounted ceiling presence detector that uses high-frequency sensing to detect very small human movements. It suits rooms where people sit, read, work at a computer or take part in meetings without making large movements. 7.2 GHz True Presence technology analyses micro-movements, including body movement caused by breathing. Choosing an appropriate detection area and sensitivity scenario helps lighting follow how the room is actually occupied, while retaining a defined relay response after people leave.
Two different detection areas need to be considered when planning the installation. True Presence micro-movement detection reaches up to Ø9 m, approximately 64 m², while movement and conventional presence detection extend to Ø15 m, or 177 m². The manufacturer's reference mounting height is 2.8 m, and the special True Presence function is intended for heights up to 4 m. The broader 2–12 m mounting range therefore does not mean breathing-related micro-movements are detected from a 12 m ceiling. Relating the required detection type to desks, seats and walking routes is a useful first step before selecting the sensor position.
Sensitivity and Bluetooth Mesh configuration
The detection area and sensitivity scenario are configured in the STEINEL Connect app. The manufacturer provides nine scenarios to accommodate quiet office work, more active spaces and environments affected by vibration. A small, quiet office needs a different response from an area containing moving machinery. Scenarios 1 and 2, intended for environments affected by vibration, disable the True Presence function and operate as conventional motion detection. This makes sensitivity a deliberate installation choice rather than an assumption that maximum sensitivity is appropriate everywhere.
Bluetooth Mesh allows the detector to operate individually or alongside compatible products in a lighting group. The app supports grouping, parameter adjustment and neighbouring-group functions, enabling the next lighting area to respond when required. The COM1 version provides one relay output for switching the connected circuit on and off. Fully automatic operation can follow room use, while semi-automatic operation requires a button press to turn the light on and leaves automatic switch-off to the detector. The S input accepts an external button, and compatible network buttons can also be assigned in the app.
The black model does not include onboard light-level measurement. If switching needs to depend on daylight, the installation must provide a compatible external brightness measurement and integrate it into the Bluetooth system. This needs to be considered when selecting equipment, particularly for workspaces with large windows. The detector itself provides presence detection and COM1 relay control, so choosing the black housing also involves this functional difference. Teach is not specified for this variant.
Timing, connected loads and surface installation
The installation manual specifies a COM1 time range of 30 seconds to 60 minutes. The current product table also lists a 20-second minimum; the available settings for the actual unit can be checked in the app. Selecting an appropriate delay gives a predictable switch-off after the room is vacated. A button preserves manual control, while pulse mode provides a 2-second output followed by an 8-second pause, for example when triggering a compatible staircase timer. The selected function should match what the connected lighting circuit is intended to do.
The installation manual rates the COM1 output for LED and electronic-ballast loads up to 600 W. For this exact article, the current product table’s limit of eight LED or fluorescent lamps also applies; the manual gives a capacitance limit of 220 µF. Lamp power, quantity and electrical behaviour need to be assessed together. Incandescent and halogen resistive loads are rated at 2000 W, which is not a universal LED rating. When planning one switched circuit, check the combined electrical characteristics of all connected lamps.
The AP housing measures 123 × 123 mm across and 45 mm deep, for surface mounting on an indoor ceiling. The black RAL 9005 finish suits dark ceilings or a deliberately contrasting interior. The surface version has confirmed IP54 protection and operates from 220–240 V AC, 50–60 Hz. High-frequency detection can respond through glass, wood or lightweight partitions, so electronic range adjustment helps keep coverage within the intended area. When choosing a location, the manual calls for at least 3 m separation from a Wi-Fi router or access point. After installation, check performance at the actual positions where people are expected to remain relatively still.
- 360° high-frequency presence detection with a separate micro-movement area.
- One COM1 relay circuit and Bluetooth Mesh configuration.
- Automatic or semi-automatic operation, button input and pulse mode.
- Indoor surface ceiling installation with a RAL 9005 housing.
Image context. The hotel photograph is a manufacturer installation example for the True Presence family and shows a white ceiling sensor. It illustrates use rather than identifying a particular interface, generation or black finish.