- Housing material Plastic
- Weight 152 g
- Number of detection zones 448
- Sensor technology Infrared (PIR)
- Sensor type Passive infrared (PIR)
- Installation UP · Flush wall mounting · dry indoor areas
- Reach Tangential r = 20 m, radial r = 4 m
- Detection angle 180° horizontal / 90° vertical
- Optimal mounting height 2 m
- Maximum mounting height 2.5 m
- Time setting 5 s – 15 min
- Twilight setting 2–1000 lx
- Sneak-by guard Yes
- Segment masking Yes
- Manual override 4 h
- Relay load Resistive 2000 W; fluorescent ECG 1500 W; uncorrected 1000 VA, series/parallel corrected 400 VA; low-voltage halogen 2000 VA
- LED load (W) < 2 W → 100 W, 2 W < P < 8 W → 300 W, > 8 W → 600 W. Capacitive load ≤ 176 µF, up to 8 LED or fluorescent lamps.
- Parallel connection Master/Master · ≤ 10
- Output type COM1
- Interface & control The COM1 relay switches mains voltage to the light. The resistive load limit is 2000 W. Up to 10 detectors can be interconnected in a wired master/master arrangement.
- Settings Potentiometers, remote control, Smart Remote
- Voltage 220–240 V AC, 50–60 Hz
- Operating temperature −20 … +50 °C
- IP rating IP20
- Dimensions (W×H×D) 78 × 94 × 94 mm (depth × width × height)
- Accessories Smart Remote 009151, RC8 559410, RC5 592806, Black square cover UP 056728
- Warranty 5 years
- Colour / RAL White RAL 9003
- Manufacturer SKU 055721
- EAN 4007841055721
Product Description
STEINEL IS 3180 COM1 switches the connected lights on when someone enters the detection area. It suits corridors and stairwells where the luminaires are controlled by switching mains voltage. The white IP20 flush-mounted model is designed for a wall in a dry indoor space. On a corridor or landing wall, only the square front is visible. The connection unit sits inside the wall.
Detection in corridors and on stairs
The PIR detector covers 180° horizontally with a 90° vertical aperture. It can detect a person crossing its field at up to 20 m. For someone walking directly towards it, the maximum is 4 m. The recommended mounting height is 2 m, within a range of 1.8–2.5 m.
On a landing, use the detection diagram to choose a position, then walk in from both flights. How early the detector picks up someone coming from above or below depends on its position, the direction of approach and any obstruction in front of the lens.
In a corridor, start with the route people actually take. A PIR element registers changes in heat as someone moves from one lens segment into the next. A position on a side wall can therefore use the longer, tangential field. At the end of a corridor, where someone walks straight towards the lens, use the radial distance to decide where the lights will first respond. The distances on the manufacturer's drawing are measured from the detector.
Detection field · Tangential r = 20 m, radial r = 4 m.
The lens divides the field into 448 switching zones and includes coverage immediately below the detector. Where an adjacent doorway should fall outside the monitored route, shrouds can mask individual lens segments while the rest of the passage remains covered. Walk the route in both directions after fitting the shrouds. A glass partition, closed door or solid stair parapet can hide a person from the PIR element even inside the outline shown on the plan.
On a landing, identify the first tread that needs to be lit and check whether someone enters the field before reaching it. If the two flights overlap, the upper flight can screen the approach from below. A second detection point may be more effective there than a longer lighting period. Extending the time helps a person finish the route after being detected, but leaves the position of the first detection unchanged.
Settings and lighting response
Choose the twilight threshold for the daylight at the detector itself. With Teach, wait until the room is at the level where electric lighting is actually needed, then store the measured value. This takes account of the local window position and reflections from the floor and walls. Choose the follow-up time for the length of a typical walk along the corridor or stairs. The threshold sets a lighting condition, while the timer determines how long the response lasts.
Settings · Potentiometers, remote control, Smart Remote · 2–1000 lx · 5 s – 15 min.
Relay load and light settings
The relay switches mains voltage to the luminaires and accepts a resistive load up to 2000 W. In a longer corridor, up to 10 detectors can share a wired master/master connection. Set the light to stay on for 5 seconds to 15 minutes. The teach function stores the local dusk level, and an external switch can keep the lights on for four hours when needed.
For LED lighting, the load limit depends on the wattage of each lamp. The total limit is 100 W for lamps below 2 W, 300 W for lamps above 2 W and below 8 W, and 600 W for lamps above 8 W. The capacitive load limit is 176 µF. A COM1 output accepts a total of up to 8 LED or fluorescent lamps.
In pulse mode the relay gives a signal lasting about two seconds. This is suitable for a staircase timer that keeps the lights on for its own preset period. Use the normal time setting when luminaires are connected directly to the detector. To size a lighting group, first identify the type and wattage of each lamp, then check the total power, lamp count and combined input capacitance of the drivers. The installation must meet all applicable limits at the same time.
Other relay load types · Resistive 2000 W; fluorescent ECG 1500 W; uncorrected 1000 VA, series/parallel corrected 400 VA; low-voltage halogen 2000 VA
Mounting, dimensions and accessories
On the flush version the square front covers the connection point in the wall. When planning a position near a door or corner, check both the clear space for the front and the depth required for the mechanism. The technical drawing gives the overall detector dimensions. Compare these with the installation location before completing the wall finish. This IP20 version suits dry indoor rooms. A square UP cover is available if a black finish is required.
STEINEL 055721 · 78 × 94 × 94 mm (depth × width × height) · 152 g · −20 … +50 °C.
Accessories · Smart Remote 009151, RC8 559410, RC5 592806, Black square cover UP 056728.
Manufacturer documents
Look for this article number on the data sheet. The installation manual covers several STEINEL models, so use the IS 3180 section for lens and mounting illustrations and select the connection diagram for the interface shown here. Use the dimension drawing when planning the mounting position and the detection diagram when assessing the direction of approach. Both drawings are also available in the image gallery.