Steinel
Estimated sourcing to our Riga store: 1-2 weeks.
Delivery to your address is counted from dispatch; for products on order, add it to the sourcing time. The carrier time is shown with the delivery method at checkout.
Quantities above available stock require sourcing of the remaining units. Check the information in your cart.
For collection, wait for confirmation that your order is ready.
- Indoor lighting
- Outdoor lighting
- Technical lighting
- LED bulbs
- LED strips and profiles
- LED power supplies
- Motion sensors and dusk switches
- Motion sensors
- Other
- Sale
Your shopping cart is empty!
Item specifics
- Housing material Plastic
- Weight 151 g
- Number of detection zones 448
- Sensor technology Infrared (PIR)
- Sensor type Passive infrared (PIR)
- Installation AP · Surface wall mounting · indoors and outdoors
- Reach Tangential r = 20 m, radial r = 4 m
- Detection angle 180° horizontal / 90° vertical
- Optimal mounting height 2 m
- Maximum mounting height 2.5 m
- Twilight setting 2–1000 lx
- Sneak-by guard Yes
- Segment masking Yes
- Parallel connection DALI-2 · Master/Slave
- Output type DALI-2 IPD
- Interface & control The IPD is an addressable DALI-2 input device. The DALI bus supplies it with power. It sends motion and light-level information to an external controller that operates the luminaires. Typical current at 16 V is 5 mA. Maximum current per IEC 62386-101 · 24 mA.
- Settings DALI-2
- Voltage DALI 12–22.5 V
- Operating temperature −20 … +50 °C
- IP rating IP54
- Dimensions (W×H×D) 65 × 95 × 95 mm (depth × width × height)
- Accessories Smart Remote 009151, Corner wall mount 035174, Black square cover AP 056711
- Warranty 5 years
- Colour / RAL White RAL 9003
- Manufacturer SKU 057350
- EAN 4007841057350
Product Description
STEINEL IS 3180 DALI-2 IPD is an addressable DALI-2 input device. It sends movement and light-level data to an external controller. Choose this version for a corridor or stairwell where the building’s DALI controller decides how the luminaires respond. The white IP54 surface-mounted housing fits directly to a wall indoors or outdoors, for example beside a building entrance. The base provides space for the wiring.
Detection in corridors and on stairs
The PIR detector covers 180° horizontally with a 90° vertical aperture. It can detect a person crossing its field at up to 20 m. For someone walking directly towards it, the maximum is 4 m. The recommended mounting height is 2 m, within a range of 1.8–2.5 m.
On a landing, use the detection diagram to choose a position, then walk in from both flights. How early the detector picks up someone coming from above or below depends on its position, the direction of approach and any obstruction in front of the lens.
In a corridor, start with the route people actually take. A PIR element registers changes in heat as someone moves from one lens segment into the next. A position on a side wall can therefore use the longer, tangential field. At the end of a corridor, where someone walks straight towards the lens, use the radial distance to decide where the lights will first respond. The distances on the manufacturer's drawing are measured from the detector.
Detection field · Tangential r = 20 m, radial r = 4 m.
The lens divides the field into 448 switching zones and includes coverage immediately below the detector. Where an adjacent doorway should fall outside the monitored route, shrouds can mask individual lens segments while the rest of the passage remains covered. Walk the route in both directions after fitting the shrouds. A glass partition, closed door or solid stair parapet can hide a person from the PIR element even inside the outline shown on the plan.
On a landing, identify the first tread that needs to be lit and check whether someone enters the field before reaching it. If the two flights overlap, the upper flight can screen the approach from below. A second detection point may be more effective there than a longer lighting period. Extending the time helps a person finish the route after being detected, but leaves the position of the first detection unchanged.
Settings and lighting response
The IPD reports the measured light level and detected movement to the DALI system. The project logic sets thresholds and delays and chooses which group should respond. For example, a corridor can be bright enough during the day even though the detector reports each arrival. When commissioning, first verify that the controller receives the input event, then check the response of the assigned group. This separates the performance of the lens from the behaviour of the lighting programme.
Settings · DALI-2 bus and external controller.
Power and data on the DALI bus
Power comes from the DALI bus (12–22.5 V). Typical current at 16 V is 5 mA. For bus sizing, the manufacturer also specifies a maximum of 24 mA according to IEC 62386-101. The system controller determines which lighting groups respond to movement and how the light-level reading is used.
Select this input device for a system with a DALI application controller and bus power supply. Mains power for the luminaires and commands for lighting control are separate parts of the design. When another IPD is added, allocate an address, allow for its bus current and define how its events will be used. Several detection points along a corridor can serve one lighting zone if the external controller is configured accordingly.
Mounting, dimensions and accessories
The square base of this surface model sits on the wall. Check its footprint against the door frame, cable entry and nearest corner using the dimension drawing. For outdoor use, follow the manufacturer's instructions for assembling the housing and sealing the cable entry. IP54 describes the assembled unit's protection against dust and splashing water. On a dark wall the visible white finish can be changed with the matching black AP cover.
STEINEL 057350 · 65 × 95 × 95 mm (depth × width × height) · 151 g · −20 … +50 °C.
Accessories · Smart Remote 009151, Corner wall mount 035174, Black square cover AP 056711.
Manufacturer documents
Look for this article number on the data sheet. The installation manual covers several STEINEL models, so use the IS 3180 section for lens and mounting illustrations and select the connection diagram for the interface shown here. Use the dimension drawing when planning the mounting position and the detection diagram when assessing the direction of approach. Both drawings are also available in the image gallery.