Item specifics

  • Housing material Plastic
  • Weight 178 g
  • Number of detection zones 448
  • Sensor technology Infrared (PIR)
  • Sensor type Passive infrared (PIR)
  • Installation AP · Surface wall mounting · indoors and outdoors
  • Reach Tangential r = 6 / 20 m, radial r = 3 / 4 m
  • Detection angle 180° horizontal / 90° vertical
  • Optimal mounting height 2 m
  • Maximum mounting height 2.5 m
  • Time setting 5 s – 15 min
  • Twilight setting 2–1000 lx
  • Sneak-by guard Yes
  • Segment masking Yes
  • Manual override 4 h
  • Relay load S1/S2 · ≥ 100 mA @ 12 V AC/DC · incandescent/halogen lamps ≤ 2000 W
  • LED load (W) < 2 W → 100 W, 2 W < P < 8 W → 300 W, > 8 W → 600 W. Capacitive load ≤ 176 µF.
  • Parallel connection Master/Master
  • Output type PF
  • Interface & control The PF model has a volt-free S1/S2 relay contact and a separate mains supply for the sensor. Minimum switching load is 100 mA at 12 V AC/DC. STEINEL specifies wired master/master interconnection.
  • Settings Potentiometers, remote control, Smart Remote
  • Voltage 220–240 V AC, 50–60 Hz
  • Operating temperature −20 … +50 °C
  • IP rating IP54
  • Dimensions (W×H×D) 65 × 95 × 95 mm (depth × width × height)
  • Accessories Smart Remote 009151, RC8 559410, RC5 592806, Corner wall mount 035174, Black square cover AP 056711
  • Warranty 5 years
  • Colour / RAL White RAL 9003
  • Manufacturer SKU 010508
  • EAN 4007841010508

Product Description

STEINEL IS 3180 PF is a wall-mounted motion detector for systems that need a volt-free contact. Its relay can signal movement to a separate control circuit, such as a corridor lighting controller with a contact input. The white IP54 surface-mounted housing fits directly to a wall indoors or outdoors, for example beside a building entrance. The base provides space for the wiring.

Detection in corridors and on stairs

The PIR detector covers 180° horizontally with a 90° vertical aperture. It can detect a person crossing its field at up to 20 m. For someone walking directly towards it, the maximum is 4 m. The recommended mounting height is 2 m, within a range of 1.8–2.5 m.

On a landing, use the detection diagram to choose a position, then walk in from both flights. How early the detector picks up someone coming from above or below depends on its position, the direction of approach and any obstruction in front of the lens.

In a corridor, start with the route people actually take. A PIR element registers changes in heat as someone moves from one lens segment into the next. A position on a side wall can therefore use the longer, tangential field. At the end of a corridor, where someone walks straight towards the lens, use the radial distance to decide where the lights will first respond. The distances on the manufacturer's drawing are measured from the detector.

Detection field · Tangential r = 6 / 20 m, radial r = 3 / 4 m.

The lens divides the field into 448 switching zones and includes coverage immediately below the detector. Where an adjacent doorway should fall outside the monitored route, shrouds can mask individual lens segments while the rest of the passage remains covered. Walk the route in both directions after fitting the shrouds. A glass partition, closed door or solid stair parapet can hide a person from the PIR element even inside the outline shown on the plan.

On a landing, identify the first tread that needs to be lit and check whether someone enters the field before reaching it. If the two flights overlap, the upper flight can screen the approach from below. A second detection point may be more effective there than a longer lighting period. Extending the time helps a person finish the route after being detected, but leaves the position of the first detection unchanged.

Settings and lighting response

Choose the twilight threshold for the daylight at the detector itself. With Teach, wait until the room is at the level where electric lighting is actually needed, then store the measured value. This takes account of the local window position and reflections from the floor and walls. Choose the follow-up time for the length of a typical walk along the corridor or stairs. The threshold sets a lighting condition, while the timer determines how long the response lasts.

Settings · Potentiometers, remote control, Smart Remote · 2–1000 lx · 5 s – 15 min.

Volt-free relay and load limits

The detector has a separate 220–240 V AC supply. The control circuit connects to relay terminals S1/S2. The manufacturer specifies a minimum switching load of 100 mA at 12 V AC/DC. Several detectors can be interconnected in wired master/master operation. The stay-on time is adjustable from 5 seconds to 15 minutes.

For LED lighting, the load limit depends on the wattage of each lamp. The total limit is 100 W for lamps below 2 W, 300 W for lamps above 2 W and below 8 W, and 600 W for lamps above 8 W. The capacitive load limit is 176 µF.

Choose PF when the next device in the system has an input for a volt-free contact. PF refers to the relay contact. The detector electronics have their own mains supply. This distinction matters when replacing a detector connected to a building control panel. Pulse mode gives a signal of about two seconds to a staircase timer. If the contact switches a lighting load, use the PF data sheet to check that particular load.

Mounting, dimensions and accessories

The square base of this surface model sits on the wall. Check its footprint against the door frame, cable entry and nearest corner using the dimension drawing. For outdoor use, follow the manufacturer's instructions for assembling the housing and sealing the cable entry. IP54 describes the assembled unit's protection against dust and splashing water. On a dark wall the visible white finish can be changed with the matching black AP cover.

STEINEL 010508 · 65 × 95 × 95 mm (depth × width × height) · 178 g · −20 … +50 °C.

Accessories · Smart Remote 009151, RC8 559410, RC5 592806, Corner wall mount 035174, Black square cover AP 056711.

Manufacturer documents

Look for this article number on the data sheet. The installation manual covers several STEINEL models, so use the IS 3180 section for lens and mounting illustrations and select the connection diagram for the interface shown here. Use the dimension drawing when planning the mounting position and the detection diagram when assessing the direction of approach. Both drawings are also available in the image gallery.

Related products

Explore other options and products linked to this item.

STEINEL IS 3180 PF PIR motion detector, surface-mounted, 180°, IP54, white — 010508
STEINEL IS 3180 PF PIR motion detector, surface-mounted, 180°, IP54, white — 010508
125.55€